Calibration and Maintenance of Mechanical Pipettes in the Modern Wastewater Laboratory

 

Mechanical air-displacement pipettes (mechanical pipettes) are widely used in the modern wastewater laboratory. They are a convenient means of dispensing a wide variety of volumes quickly and efficiently, eliminating carryover and time consuming cleaning procedures.  Mechanical pipettes must be tested and maintained regularly to ensure proper operation, much like any other laboratory instrument.  Failure to do so can lead to gross error in test results.  This video presentation will provide a step by step process for checking accuracy (calibration) and performance using the analytical balance commonly used for suspended solids testing.  This presentation is a must for all laboratory analysts and technicians.  (Windows Media Player is required for viewing).

 

High-bandwidth video (1.3 Mbps)

 

Low-bandwidth video (205 Kbps)


This video was produced by the Wisconsin State Laboratory of Hygiene.

 

Resources:

 

Presentation: Calibration of Mechanical Pipettes in the Modern Wastewater Laboratory (PDF)

Pipette Performance Check SOP (PDF)

Spreadsheet for Calculating Pipette Acceptance (MS EXCEL)

Quarterly Worksheet for Calculating Pipette Acceptance (PDF)

Annual Worksheet for Calculating Pipette Acceptance (PDF)

Z-Factor Table (PDF)

Calculations used for Verifying Pipette Calibration (PDF)



Beach Water Collection for E. Coli Testing

Using the appropriate sampling protocol to collect beach water samples for E. coli testing is critical to effectively protect the health of public beach users.  This 12 minute video provides instructions on how to properly collect beach water samples for E. coli testing.  Public health sanitarians, resort owners and anyone required to test swimming beaches for E. coli will find this video a valuable resource. (Windows Media Player is required for viewing).

High-bandwidth video (2 Mbps)

Low-bandwidth video (81 Kbps)

This video was produced by the Wisconsin State Laboratory of Hygiene, with funding provided by the State Lab of Hygiene, the Wisconsin Department of Natural Resources and the Wisconsin Department of Health and Family Services.


Reports

Report of the 2005 Environmental Laboratory Survey by the WSLH
in cooperation with the Association of Public Health Laboratories (APHL)

 

Environmental Health Pamphlets

Atrazine Screening Test
Published by the Wisconsin State Laboratory of Hygiene

Collecting Inorganic Samples Under SDWA 
(Note: PowerPoint version is now available)
Published by the Wisconsin State Lab of Hygiene

 

Copper in Drinking Water
Published by the Wisconsin DNR

 

Earwigs in Your Well
Published by the Wisconsin DNR

 

Fluoride for Your Children
Published by the Dane County Health Department

 

Interpreting Your Results
Published by the Wisconsin State Lab of Hygiene

 

Iron Bacteria Problems in Wells
Published by the Wisconsin DNR

 

Lead in Drinking Water
Published by the Wisconsin DNR

 

Water System Testing: Lead and Copper
Published by the Wisconsin State Lab of Hygiene

 

Nitrate in Drinking Water
Published by the DHFS & Wisconsin DNR

 

Pesticides in Drinking Water
Published by the Wisconsin DNR

 

Collecting Bacteriological and Nitrate Test Samples Under the SDWA
Published by the Wisconsin State Lab of Hygiene

 

Collecting Nitrate and Nitrate in Drinking Water Samples Under the SDWA
Published by the Wisconsin State Lab of Hygiene


 

Environmental Laboratory Training Presentations

Water Chemistry Presentation
By the Wisconsin State Lab of Hygiene

Results of Assessments of the Effects of Holding Times On E. coli Concentrations In Environmental Samples or Download PowerPoint file
By the Wisconsin State Lab of Hygiene, USEPA and DynCorp/CSC Biology Studies Group

 

PowerPoint: Arsenic In Drinking Waters  or in Adobe Acrobat format
By the Wisconsin State Lab of Hygiene and Wisconsin DNR

 

PowerPoint: Who Wants to be a Phosphorus and Ammonia Expert?
By the Wisconsin State Lab of Hygiene and Wisconsin DNR

 

Evaluation of Preliminary Distillation Prior to Ion Selective Electrode Determination of Ammonia in Municipal Wastewater Effluent (pdf)
By the Wisconsin State Lab of Hygiene and Wisconsin DNR

 

PowerPoint: Programming the Hach DR2010 Colorimeter
By the Wisconsin State Lab of Hygiene and Wisconsin DNR

 

PowerPoint: QA/QC for Wastewater Laboratory Testing
By the Wisconsin State Lab of Hygiene and Wisconsin DNR

 

PowerPoint: Biochemical Oxygen Demand 101
By the Wisconsin State Lab of Hygiene

 

PowerPoint: DO Probe Theory and Troubleshooting
By the Wisconsin State Lab of Hygiene

 

PowerPoint: Dilution Water Delivery Tube Disinfection
By the Wisconsin State Lab of Hygiene


 

Clinical Metals Presentations

Childhood Lead Poisioning
By the Wisconsin State Lab of Hygiene

Choosing a Blood Lead Lab
By the Wisconsin State Lab of Hygiene

 

Erythrocyte Protoporphyrin
By the Wisconsin State Lab of Hygiene

 

Filter Paper Blood Lead Testing
By the Wisconsin State Lab of Hygiene

 

Toxic Elements
By the Wisconsin State Lab of Hygiene


 

Environmental Laboratory Forms

Request for Laboratory Evaluation of a Marketed Sanitizer
By the Wisconsin State Lab of Hygiene. Fillable pdf format

Sample Test Request Form for Bacteria, Nitrate or Fluoride
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Iron Bacteria
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Copper or Lead
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Atrazine
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Arsenic
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Pool sampling
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Beaches
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Sulfate-Reducing bacteria
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Radon in Air
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Radon 222
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Radioactivity in Water
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Helicobacter pylori
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 

Sample Test Request Form for Heterotrophic plate count and Pseudomonas aeruginusa
By the Wisconsin State Lab of Hygiene. Fillable pdf format

 
Wisconsin State Laboratory of Hygiene
 
Clinical Laboratories
465 Henry Mall
Madison WI 53706
Ph: 608-262-1293
1-888-494-4324
Fax: 1-608-262-3257
Environmental Laboratories
2601 Agriculture Drive
Madison WI 53718
Ph: 608-224-6202
1-800-442-4618
Fax: 1-608-224-6213
Walton Commons
2810 Walton Commons West
Madison, WI 53718
Help Desk: 608-221-6262
Fax: 1-608-221-6297

Copyright © 2008 Board of Regents, University of Wisconsin System
Locations | Contact | Legal Notices | Acceptable Use | Privacy Policy

Feedback, questions or accessibility issues: webmaster@mail.slh.wisc.edu
Last Update: 8:57:20 AM CST, Wednesday January 9 2008