ETS is a major contributor to indoor air pollution in
environments where smokers are present.
Environmental tobacco smoke is an aerosol consisting of both vapor and particulate
phases.
Tracers of ETS used in the past include respirable or total suspended
matter, CO, nicotine, 3-ethenylpyridine, Solanesol , N-nitrosoamines
and aromatic hydrocarbons. Of these tracers, only 3-ethenylpyridene(vapor)
and Solanesol(particulate) are unique to ETS.
This analysis uses TD-GCMS instrumentation. The active sampler consists
of a Thermal Desorption Tube attached to a sampling pump. The suggested
sampling parameters are as follows: flow rate of 50cc/min and the
collection volume should be between 10-50 liters which is dependent
on expected levels of interference compounds and requested tracer
compound.

|